企业信息

    上海邑斯自动化科技有限公司

  • 3
  • 公司认证: 营业执照已认证
  • 企业性质:
    成立时间:
  • 公司地址: 上海市 金山区 枫泾镇 新元村 上海市金山区枫泾镇泾商路99弄3218
  • 姓名: LY
  • 认证: 手机已认证 身份证未认证 微信已绑定

    西门子 G120 3AC 500-690V 功率模块

  • 所属行业:电气 工控电器 DCS/PLC系统
  • 发布日期:2022-07-16
  • 阅读量:60
  • 价格:面议
  • 产品规格:齐全
  • 产品数量:1000.00 台
  • 包装说明:全新包装
  • 发货地址:上海金山枫泾新元村  
  • 关键词:西门子,G120,3AC,500-690V,功率模,制动电阻,直流侧功率部件,G120模块化设计变频器功率模块

    西门子 G120 3AC 500-690V 功率模块详细内容

    西门子 G120 3AC 500-690V 功率模块 

    型号

    6SL3210-1PH31-7CL0

    6SL3210-1PH32-1CL0

    6SL3210-1PH32-5CL0

    6SL3000-1BH32-5AA0

    Power Modules

    跳转到

    概述
    集成
    技术规范
    特性曲线
    尺寸图

    概述

    PM240‑2 Power Modules – 0.55 kW to 250 kW (0.75 hp to 400 hp), IP20 degree of protection

    PM240‑2 Power Modules, frame sizes FSA to FSG (with Control Unit and Operator Panel)

    The PM240‑2 Power Modules are based on a new hardware platform. This permits an increase in power density as well as the application of innovative cooling concepts (push-through technology) with especially high requirements in terms of control cabinet cooling.

    Furthermore, the PM240-2 Power Module is also suitable for use in safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

    The PM240‑2 Power Modules in frame sizes FSA to FSF are available both with and without an integrated line filter class A of compact design for 200 V, 400 V and 690 V line voltages (except PM240‑2 frame sizes FSD to FSF: 200 V). The PM240‑2 Power Modules in frame size FSG are available with an integrated line filter Category C3 of compact design for 400 V and 690 V line voltages, also with integrated line filter Category C2 for a line voltage of 400 V. In addition, a DC link reactor is integrated in the PM240‑2 Power Modules, frame sizes FSD to FSG, and therefore no line reactor is required.

    The PM240-2 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

    The PM240‑2 Power Module has an integrated braking chopper. In generating mode, the excess energy of the DC link can be dissipated by means of an optional braking resistor.

    The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

    Push-through variant

    Example: PM240‑2 Power Modules, degree of protection IP20, push-through variant, frame sizes FSD to FSF (with Control Unit and Operator Panel)

    The push-through variants in the frame sizes FSA to FSF allow the cooling fins of the Power Modules to be pushed through the rear panel of the control cabinet. Push-through variants should be used in applications where the amount of power loss generated inside the control cabinet itself must be minimized.

    Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
    For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

    PM250 Power Modules – 7.5 kW to 90 kW (10 hp to 125 hp), IP20 degree of protection

    PM250 Power Modules, frame sizes FSC to FSF

    PM250 Power Modules are suitable for a large number of applications in general mechanical engineering. Any braking energy is directly fed back into the line supply (four-quadrant applications – a braking chopper is not required).

    The PM250 Power Module features an absolutely unique technology – Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not converted into heat in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced.

    Further, the innovative circuit design reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement.

    The permissible cable lengths between converter and motor are limited (for max. permissible cable lengths, see Integration). Longer cables can be used if output reactors are connected (see section Load-side power components).

    Frame sizes FSD to FSF of the PM250 Power Modules are available both with as well as without integrated line filter class A.

    For frame size FSC of the PM250 Power Module with an integrated line filter class A, an additional base filter of class B is available for achieving class B (see section Line-side components).

    The PM250 Power Module is also designed for safety-oriented applications. In conjunction with a fail-safe Control Unit, the drive can be transformed into a Safety Integrated Drive (see section Control Units).

    The PM250 Power Modules with integrated line filter class A are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded TN/TT systems and non-grounded IT systems.

    Note:

    Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.
    For more information, see Shield connection kits for Control Units and Power Modules in section Supplementary system components.

    西门子 G120 3AC 500-690V 功率模块 


    西门子 G120 3AC 500-690V 功率模块 


    http://17621747610.b2b168.com
    欢迎来到上海邑斯自动化科技有限公司网站, 具体地址是上海市金山区枫泾镇上海市金山区枫泾镇泾商路99弄3218,联系人是LY。 主要经营电气相关产品。 单位注册资金未知。 价格战,是很多行业都有过的恶性竞争,不少厂家为了在价格战役中获胜,不惜以牺牲产品质量为代价,而我们公司坚决杜绝价格战,坚持用优质的原材料及先进的技术确保产品质量,确保消费者的合法利益。